Blood Warrior - a dead 1994 arcade board repair

Kaneko Blood Warrior(1994)

Board in decent condition, a few light scratches on the bottom board but tested OK. The client said it was working before with a “RAM CHECK OK” on screen.

Diagnosis

Turns on with black screen only. Sync signal is probably right. Preliminary test shows the CPU has been watchdog reset periodically.

Dumped U124, U513, U514, all identical to Internet ROMs.

Turns out there’s a middle connector needs to push harder when assembled. Now I can get a “RAM CHECK OK” message. The next POST message never appears, and after 12 seconds it restart RAM check again.

There is a board corner damage around a connector on bottom board. Might have been dropped before?

The repair

Since it was working before, and it’s been loop reset with known good ROMs, take a good look at the ROMs.

The 3 ROMs to a custom chip traces are good. But the custom chip, which I believe is to decode the address and send it through a 74LS244 to the CPU board, has 2 sides of SMD legs detached. Possibly from previous drop damage, or the fact the two boards needs bit of force to separate them may cause the detached legs.

Resolder those legs. Game boots.

Fully repaired.